Install ntp service windows 2008




















If you are not a fan of the Windows PowerShell, then this will truly come in handy. To get started, open the registry editor. The windows registry will be launched as shown below. On the right pane.

For the changes to come into effect, you need to reboot the NTP server by heading to the services Window. Once you have set up your NTP server, you can use the following commands to verify various aspects of the server:. We cannot stress enough how important it is to maintain accurate time and date settings on your server.

Archived Forums. Network Infrastructure Servers. Sign in to vote. Hi, I am a Linux guy. Thanks, vrp. Friday, September 3, AM. Hello, as said before the WSUS server will not give the updates to the client, the client checks the WSUS server if updates are available and then download and install them.

Have never seen that updating the machine reset the time to different one. Marked as answer by linux07 Wednesday, January 25, AM. Monday, January 17, PM. So, if it is the case, you don't really need to have a NTP server. What you said is right. Friday, September 3, PM. Thanks for your reply. I want NTP server should synchronize with local hardware time not with time. Could you please advice. The equations use the value measured in seconds the value in parentheses.

The output presents the clock rate in seconds. To see the SystemClockRate value in clock ticks, use the following formula:. For example, if SystemClockRate is 0. For full descriptions of the configurable parameters and their default values, see Config entries later in this article. The following examples show how to apply these calculations for Windows Server R2 and earlier versions. In this case, if you want to set the clock back slowly, you would also have to adjust the values of PhaseCorrectRate or UpdateInterval in the registry to make sure that the equation result is TRUE.

The Windows Time service stores a number of configuration properties as registry entries. It stores configuration information that the policies define in the Windows registry, and then uses those registry entries to configure the registry entries specific to the Windows Time service.

As a result, the values defined by Group Policy overwrite any pre-existing values in the Windows Time service section of the registry. Some of the preset GPO settings differ from the corresponding default Windows Time service registry entries. Windows loads these settings into the policy area of the registry under the following subkey:.

Then Windows uses the policy settings to configure the related Windows Time service registry entries under the following subkey:. The following table lists the policies that you can configure for the Windows Time service, and the registry subkeys that those policies affect. When you remove a Group Policy setting, Windows removes the corresponding entry from the policy area of the registry. This information is provided as a reference for use in troubleshooting and validation.

Windows registry keys are used by W32Time to store critical information. Don't change these values. Modifications to the registry are not validated by the registry editor or by Windows before they are applied. If the registry contains invalid values, Windows may experience unrecoverable errors. Some of the parameters in the registry are measured in clock ticks and some are measured in seconds.

To convert the time from clock ticks to seconds, use these conversion factors:. Note Zero is not a valid value for the FrequencyCorrectRate registry entry. HoldPeriod All versions Controls the period of time for which spike detection is disabled in order to bring the local clock into synchronization quickly. A spike is a time sample indicating that time is off a number of seconds, and is usually received after good time samples have been returned consistently.

The default value on domain members is 5. The default value on stand-alone clients and servers is 5. LargePhaseOffset All versions Specifies that a time offset greater than or equal to this value in 10 -7 seconds is considered a spike. A network disruption such as a large amount of traffic might cause a spike.

A spike will be ignored unless it persists for a long period of time. The default value on domain members is The default value on stand-alone clients and servers is It contains reserved data that is used by the Windows operating system, and any changes to this setting can cause unpredictable results. MaxAllowedPhaseOffset All versions Specifies the maximum offset in seconds for which W32Time attempts to adjust the computer clock by using the clock rate.

When the offset exceeds this rate, W32Time sets the computer clock directly. The default value for domain members is The default value for stand-alone clients and servers is 1. The default value for stand-alone clients and servers is MaxNegPhaseCorrection All versions Specifies the largest negative time correction, in seconds, that the service makes.

If the service determines that a change larger than this is required, it logs an event instead. This value means that the service always corrects the time. The default value for domain controllers is , 48 hrs. The default value for stand-alone clients and servers is 54, 15 hrs. MaxPollInterval All versions Specifies the largest interval, in log2 seconds, allowed for the system polling interval. Note that while a system must poll according to the scheduled interval, a provider can refuse to produce samples when requested to do so.

The default value for domain controllers is MaxPosPhaseCorrection All versions Specifies the largest positive time correction in seconds that the service makes. MinPollInterval All versions Specifies the smallest interval, in log base 2 seconds, allowed for the system polling interval. Note that while a system does not request samples more frequently than this, a provider can produce samples at times other than the scheduled interval.

The default value for domain controllers is 6. PhaseCorrectRate All versions Controls the rate at which the phase error is corrected. Specifying a small value corrects the phase error quickly, but might cause the clock to become unstable. If the value is too large, it takes a longer time to correct the phase error. The default value on domain members is 1. The default value on stand-alone clients and servers is 7. Note Zero is not a valid value for the PhaseCorrectRate registry entry.

PollAdjustFactor All versions Controls the decision to increase or decrease the poll interval for the system. The larger the value, the smaller the amount of error that causes the poll interval to be decreased. RequireSecureTimeSyncRequests Windows 8 and later versions Controls whether or not the DC will respond to time sync requests that use older authentication protocols. If enabled set to 1 , the DC will not respond to requests using such protocols.

This is a boolean setting, and the default value is 0. SpikeWatchPeriod All versions Specifies the amount of time that a suspicious offset must persist before it is accepted as correct in seconds. The default value on stand-alone clients and workstations is We have a couple around the library. February 12, at AM. Thanks for great guide. I wan to know, how many client can use this kind of NTP server that rub by W32time? April 01, at AM.

June 24, at AM. July 02, at AM. November 10, at AM. January 22, at AM. November 11, at AM. March 09, at AM. Could you please guide me step by step configuration.

April 12, at AM. May 27, at AM. Thanks a mil. May 30, at AM. June 15, at AM. November 16, at AM. March 03, at AM. June 09, at AM. Your email address will not be published. Instructions on how to disable Skype v8 automatic updates. Pretty sweet so far. I can finally decommis Enable NTPServer. Exit Registry Editor. Tips Make sure W32Time is set to Automatic startup mode.



0コメント

  • 1000 / 1000